Jiangsu ChangSheng Electric Appliance Co., Ltd

To be No.1 in thermostat industry.

Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsThermal Cutoff Fuse

CSRY 250V 10A Thermal Cutoff Fuse , Non-Recloseable Thermal Fuse Switch

Good quality AC Thermal Protector for sales
Good quality AC Thermal Protector for sales
A korean motor manufacturer

—— Kevin King

I'm Online Chat Now

CSRY 250V 10A Thermal Cutoff Fuse , Non-Recloseable Thermal Fuse Switch

China CSRY 250V 10A Thermal Cutoff Fuse , Non-Recloseable Thermal Fuse Switch supplier
CSRY 250V 10A Thermal Cutoff Fuse , Non-Recloseable Thermal Fuse Switch supplier CSRY 250V 10A Thermal Cutoff Fuse , Non-Recloseable Thermal Fuse Switch supplier CSRY 250V 10A Thermal Cutoff Fuse , Non-Recloseable Thermal Fuse Switch supplier CSRY 250V 10A Thermal Cutoff Fuse , Non-Recloseable Thermal Fuse Switch supplier CSRY 250V 10A Thermal Cutoff Fuse , Non-Recloseable Thermal Fuse Switch supplier

Large Image :  CSRY 250V 10A Thermal Cutoff Fuse , Non-Recloseable Thermal Fuse Switch

Product Details:

Place of Origin: China
Brand Name: DESHENG
Certification: CCC
Model Number: CSRY01

Payment & Shipping Terms:

Minimum Order Quantity: 1000pcs
Packaging Details: 10,000pcs per carton
Delivery Time: 10-15 days on order date
Payment Terms: T/T L/C D/P
Supply Ability: 300,000pcs per month
Detailed Product Description
Product Name: Thermal Cutoff Fuse Rated Disconnection Temperature: AC250V 10A,15A
Keep Temperature: Th Tf-15℃ The Highest Environmental Temperature: Tm 320℃
High Light:

resettable thermal fuse

,

thermal fuse switch

Hydraulic Mechanical Capillary Temperature Controlled Thermostat For Boiler And Oven
 
 
Electro mechanical temperature controls with capillary phial
Rathgeber's capillary tube thermostats are used all over the world to control and limit temperatures (temperature range from -30°C to +400°C)
Rathgeber's products are manufactured professionally in accordance with latest technology and in compliance with the appropriate standard DIN EN 60730.
They operate safely and reliably, provided that specification required is clear at the start of the project.
Rathgeber supply temperature controls, sensors and limiters with phial and with capillary tube length according to customer specification for applications such as:
 

  • Boilers
  • Night storage heaters
  • Heat exchangers
  • Water heaters
  • Laboratory equipment
 
  • Ovens of domestic cookers
  • Washing machines
  • Dishwashers
  • Deep fat fryers
  • High pressure jet washers

 
 
Principle of operation
The pressurised system which operates according to the principle of expansion of liquid is the heart of a hydraulic thermostat.
It comprises phial, capillary tube and diaphragm.
Following an increase in temperature at the phial, the liquid expands in the capillary tube, causing the diaphragm to move. This movement activates a snap-action switch, causing opening or closing of switch contacts.
It is clear that a high degree of precision is required in manufacture, as a change in temperature of 1°K can cause a movement of the diaphragm between 0,002mm - 0,01mm.
It is therefore absolutely essential that the phial and capillary tube should not be squashed or otherwise damaged!
The thermostats are calibrated at room temperature 20°C. If during operation the capillary tube and diaphragm are subjected to a higher temperature the switching point will be changed. If the ambient temperature (TU) is known in advance this can be taken into account during the calibration process. Alternatively it is possible to compensate for the influence of ambient temperature upon the liquid at the diaphragm by fitting a bi-metal device.

  Normally close, open on temperature rise, automatic reset, Earth Terminal Option

Working voltage and current

16 Amps @ 250 Vac and 16 Amps @ 400 Vac

Ø Phial  diameter

3/6 mm

Cycles life

100,000 cycles

Open temperature

-35°C to 350°C  

Temperature Tolerance

±3°C, ±4°C, ±5°C, ±8°C, ±10°C, ±12°C

Differential Temperature

depending on open temperature

Contact resistance

≤100 m 

Capillary length

300~ 3000 mm; other lengths available upon request

Body temperature

T120 / T150 

Faston Terminal Connections

6,3x0,8 mm DIN46244

Contact Closure Resistance:

≤50mΩ

Insulation Resistance

≥100MΩ

Speed of response

1.0℃/min

.Min. electric current

200mA

 
 

Typical
 Model

Operating temperature

Switch

Voltage
(V)

Current
(A)

Maximum
Temperature
Sensing part(℃)

H

L

OFF(℃)

DIFF(K)

OFF(℃)

DIFF(K)

WY35A-Ⅰ

35±4

5±3

-35±4

5±3

CSRY 250V 10A Thermal Cutoff Fuse , Non-Recloseable Thermal Fuse Switch

400/250

16

70

WY75A-Ⅰ

75±3

5±3

25±5

5±3

CSRY 250V 10A Thermal Cutoff Fuse , Non-Recloseable Thermal Fuse Switch

400/250

16

110

WY110A-Ⅰ

110±4

6±4

60±8

6±3

CSRY 250V 10A Thermal Cutoff Fuse , Non-Recloseable Thermal Fuse Switch

400/250

16

120

WY190A-Ⅰ

190±8

8±4

50±8

8±4

CSRY 250V 10A Thermal Cutoff Fuse , Non-Recloseable Thermal Fuse Switch

400/250

16

160

WY250B-Ⅰ

250±10

10±5

120±12

10±5

CSRY 250V 10A Thermal Cutoff Fuse , Non-Recloseable Thermal Fuse Switch

400/250

16

250

        WY350A-Ⅰ

340±12

12±6

60±15

12±6

CSRY 250V 10A Thermal Cutoff Fuse , Non-Recloseable Thermal Fuse Switch

400/250

16

400

 
 
Applications:
 
■ - 10 / +16 Refrigeration
■ -35 / +35 Fridge
■ 0 / 40 Ambient
■ 0 / 85 Boliers / Water heaters
■ 0 / 93 Dishwashers
■ 30 / 110 Bain Marie
■ 60 / 200 Deep-fryer
■ 50 / 250 Oven
■ 50 / 300 Oven
■ Other ranges upon request
 
 
Competitive Advantage:
 

1. VDE CE CQC Approved.

2. A variety of coating configuration and shell materials are available according to different usages

3. RoHs (2002/95/EC Directive) compliant

4. Customized adjuster rod lengths and requirements are accepted

5. To supply adjustable knob, bezel and mounting screws

6. Adjustable temperature with positive contact separation

7. Mounting bushings/fittings and various sealing bushings are available

8. SPST or SPDT contact configuration

9. Durable stainless steel or copper construction

 
 
CSRY 250V 10A Thermal Cutoff Fuse , Non-Recloseable Thermal Fuse Switch

Contact Details
Jiangsu ChangSheng Electric Appliance Co., Ltd

Contact Person: Miss. Wendy zhang

Tel: 86-519-85920008

Fax: 86-519-85920222

Send your inquiry directly to us (0 / 3000)